📍 Jatlan Head, Mirpur AJK  ·  0300 5140524  ·  05827 403026  ·  info@katariaengineering.com اردو · Today: Material prices
Kataria Engineering
Home / Engineering Tools / Concrete & Aggregate Tests

Concrete Mix Design (ACI)

ACI 211.1 concrete mix design: water, cement, sand and crush per m³ and per bag from f′c, slump, aggregate size and properties, with moisture correction.

Loading the calculator… (JavaScript is needed)

About this test

Design a normal-weight concrete mix by the ACI 211.1 method. Enter the strength, slump and your aggregate properties; get the batch weights per cubic metre and per bag of cement, corrected for site moisture.

How it's calculated

  • f′cr = f′c + 8.3 MPa (21–35 MPa, no test record)
  • Water and air from slump and maximum aggregate size (ACI tables)
  • w/c from f′cr; cement = water ÷ w/c
  • Crush volume from max size and sand FM; sand by absolute volume

Results are calculated from the values you enter using standard formulas. Download the PDF to keep a record. For certified testing, design or construction, talk to our engineers.

Need an engineer for your project?

Testing, design and construction across Azad Kashmir & Punjab. Call or WhatsApp us.